A123 RX Packs can be tricky to deturming how much is left in the pack by checking voltage alone. Variations in connectors and length of wire can have a big impact on actual volt readings when loaded. Using an RRC1000 digital voltmeter with load capability of 0.0A, .5A, 1A and 1.5A we get the following results measuring a 2300 2S RX pack with 6″ 20 g silicone JR pigtail and the included 22 guage battery checker pigail with the meter. Note: the meter (which ever you are using) is reading the voltage on it’s board, not at the pack. The voltage at the pack will actually be higher by the voltage drop across your checkers connector, pigtail, checker/pack connector and the pigtail on the pack. Here are the results we measured at varous loads. Room temperature was 74 degrees F, each load held aproximately 5 seconds before reading taken.
State Of Charge | No Load Resting Voltage | .5 Amp Load | 1.0 Amp Load | 1.5 Amp Load | 40% | 6.58v | 6.37v | 6.18v | 6.09v | 30% | 6.52v | 6.38v | 6.17v | 6.06v | 20% | 6.45v | 6.32v | 6.19v | 6.08v | 10% | 6.38v | 6.25v | 6.14v | 6.04v | 0% | 5.43v | 5.19v | 5.08v | 4.98v |
---|
As can be seen from the data above, at some loads, the pack actually increased slightly in voltage as we went down even though the overall trend was lower in voltage. Note this test was not over a multitude of packs which would be more accurate and likely nuetralize the unexpected results mentioned.
Notice how little the pack is falling off in voltage and that the biggest consistant drop is in the resting voltage column, not a result I expected.
Notice the results at 0% capacity remaining as measured by my charger/discharger. As it is important to understand the context of the data and how I was checking the voltages, it is also important to understand the context of the data and how I was discharging the pack in 10% steps until empty (more explanined below) All discharges to make this chart after the initial 60% discharge were at 1.1A and in 230mah steps. The discharge harness was made from 22guage wire, 24″ long and plugged only into the JR output lead on the pack. Even though after 5 seconds of holding the load, I got the voltages above on the 0% line, putting the pack back on the discharger and trying to discahrge it some more resulted in the pack falling off to the 4V cut off (the empty point) in only about 10 to 15 seconds. Yet, I was still able to measure almost 1.5 higher than that when the pack had come off the first discharge to empty and been allowed to set for only 10 minutes before I measured anything. We can see that a wide range of voltages over 5 to 15 seconds with differing loads were all the same thing – EMPTY! Pay attention to the context of everything or you’ll get fooled! Because the context of how you are checking the voltage has such an impact on the reading, you should check your packs the same way every time with religious zeal.
A123 Systems cells ability to hold a strong voltage under load all the way until they are empty is one of the primary reasons they are so popular as RX packs, yet it is the very reason they are somewhat more challenging to voltmeter check from flight to flight.
To devise your own chart, cycle the pack to deturmine it’s actual value (ours was 2250), recharge, then set your chargers limiter to 60% of the actual value (ours was set to 1350) and discharge at capacity/2 (we used 1.1amp for our pack). After you’ve discharged it to this point, take the reading with the equipment and through the switches or whatever you have installed in your ship. Now you will know the readings at the 60% discharged (40% remaining) point. This is where you should be recharging any mission critical pack such as a TX or RX pack. To arrive at another row of data aproximately 10% further down in the pack, we simply set the limiter to 230mah and repeated the discharge. Repeat for each line of data you’d like to collect. You could start from full and discharge in 230mah steps generating data for 100%,90%,80% & etc….. Science, don’t you love it!
It would be my advice to think about making your own chart so you can learn something and become firmiliar with the voltage drop across all the gear in your model. You’ll be measuring the pack across a switch harness in most cases which will give you lower voltage readings than these.
General practice should be to taxi the model back to the pits, and before you’ve turned it off, plug your loaded volt meter in, turn off the model and take your reading immeadiately. Note your own chart for the correct cut off voltage and always recharge at the 40% remaining point. Flying below 40% is dipping into your reserves and should be avoided for any mission critical pack.